EX909 |
 |
|
| High-powered
pressure transducer |
| Capacity
: 0.1,
0.15, 0.2, 0.3, 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 7, 15, 35 mpa |
| Full
scale offset |
V |
100
± 10 |
| Zero
Output |
mV |
±
5 |
| Comprehensive
Error |
%
F.S. |
±
0.35 |
| Temperature
Effect on Zero |
%
F.S. / 10ºC |
±
0.025 |
| Temperature
Effect on Output |
%
F.S. / 10ºC |
±
0.025 |
| Repeatability |
%
F.S. |
<
0.1 |
| Hysteresis |
%
F.S. |
<
0.1 |
| Power |
VDC |
5
/ 10 |
| Operation
Temperature Range |
ºC |
-40
~ 120 |
| Compensated
Temperature Range |
ºC |
25
~ 80 |
| Input
Impedance |
Ω |
2000 |
| Output
Impedance |
Ω |
1000 |
| Insulation |
50
VDC |
100
MΩ |
| 5VDC
/ 20mADC Output pressure transmitter |
| Capacity
: 0.1,
0.15, 0.2, 0.3, 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 7, 15, 35 mpa |
| Full
scale offset |
V |
5
± 3% ( 20 mA ) |
| Zero
Output |
V
( mA ) |
0
~ 0.2 V ( 4 mA ) ( three lines ) |
| 4
mA ( two lines ) |
| Comprehensive
Error |
%
F.S. |
±
0.1 |
| Temperature
Effect on Zero |
%
F.S. / 10ºC |
±
0.05 |
| Temperature
Effect on Zero |
%
F.S. / 10ºC |
±
0.05 |
| Repeatability |
%
F.S. |
<
0.25 |
| Hysteresis |
%
F.S. |
<
0.25 |
| Power |
VDC |
12
~ 36 |
| Operation
Temperature Range |
ºC |
-40
~ 120 |
| Compensated
Temperature Range |
ºC |
25
~ 80 |
| Insulation |
50
VDC |
500
MΩ |
|

|
|