EX701A
Compression, alloy steel load cell.
Mainly used for vehicle scales, platform scale and industrial weighing system.
 Specifications  Unit  Technical Index
 Rated Output  mV / V  2.0 ± 1%
 Zero Balance  % F.S.  ± 1
 Non - Linearity  % F.S.  0.05
 Hysteresis  % F.S.  0.05
 Repeatability  % F.S.  0.03
 Creep ( 30min )  % F.S.  0.05
 Temperature Effect on Output  % F.S. / 10ºC  0.03
 Temperature Effect on Zero  % F.S. / 10ºC  0.03
 Input Impedance  Ω  385 ± 10  700 ± 15
 Output Impedance  Ω  350 ± 3  650 ± 5
 Insulation  MΩ  > 2000 / 50 VDC
 Recommended Excitation  V  10
 Maximum Excitation  V  15
 Compensated Temperature Range  ºC  - 10 ~ 50
 Operation Temperature Range  ºC  - 20 ~ 60
 Safe Overload  % F.S.  150
 Ultimate Overload  % F.S.  200
 Cable Size  mm  Ø 5 × 6000

 Red : + Excitation     Black : + Excitation     Green : + Signal     White : + Signal

Cap Size mm
0.1, 0.2, 0.3, 0.5, 0.7, 1, 2, 3, 5 10 15, 20 30
A 88 106 130 126
B 78 88 107 128
Ø1 64 76 88 106
Ø2 38 46 56 72
M 8 8 8 10


EXACT Sensor Technology Research & Development Center
www.exactchina.com