EX111 |
 |
Single-ended,
aluminum load cell.
Mainly used for platform scale, electronic balance and industrial weighing system. |
|
| Specifications |
Unit |
Technical
Index |
| Capacity
: 100, 200, 300, 500, 800, 1000, 1500, 2000 kg |
| Rated
Output |
mV
/ V |
2.0
± 10% |
| Zero
Balance |
%
F.S. |
±
2 |
| Non
- Linearity |
%
F.S. |
0.02 |
| Hysteresis |
%
F.S. |
0.02 |
| Repeatability |
%
F.S. |
0.02 |
| Creep
( 30min ) |
%
F.S. |
0.03 |
| Temperature
Effect on Output |
%
F.S. / 10ºC |
0.025 |
| Temperature
Effect on Zero |
%
F.S. / 10ºC |
0.025 |
| Input
Impedance |
Ω |
410
± 30 |
| Output
Impedance |
Ω |
350
± 3 |
| Insulation |
MΩ |
>
2000 / 50 VDC |
| Recommended
Excitation |
V |
10 |
| Maximum
Excitation |
V |
15 |
| Compensated
Temperature Range |
ºC |
-
10 ~ 40 |
| Operation
Temperature Range |
ºC |
-
20 ~ 60 |
| Safe
Overload |
%
F.S. |
150 |
| Ultimate
Overload |
%
F.S. |
300 |
| Cable
Size |
mm |
Ø 5
× 3000 |
| Platform
Size |
mm |
1200
× 1200 |
|
Red : + Excitation
Black : + Excitation Green : + Signal
White : + Signal |
|

|
| Cap
kg |
L1 |
L2 |
H1 |
H2 |
H3 |
W1 |
W2 |
M |
Table
Size |
| 750,
1000, 1500, 2000 |
176.0 |
134 |
125 |
95 |
45 |
46 |
76 |
M16
× 2.0 |
1200
× 1200 |
| 100,
200, 300, 500, 600 |
140 |
|
75 |
50 |
30 |
25 |
46 |
M10
× 20 |
800
× 1200 |
|
|