EX108A |
 |
Single-ended,
aluminum Load Cell.
Mainly used for electronic scale, electronic balance and weighing system. |
|
| Specifications |
Unit |
Technical
Index |
| Rated
Output |
mV
/ V |
2.0
± 10% |
| Zero
Balance |
%
F.S. |
±
2 |
| Non
- Linearity |
%
F.S. |
0.02 |
| Hysteresis |
%
F.S. |
0.02 |
| Repeatability |
%
F.S. |
0.02 |
| Creep
( 30min ) |
%
F.S. |
0.03 |
| Temperature
Effect on Output |
%
F.S. / 10ºC |
0.025 |
| Temperature
Effect on Zero |
%
F.S. / 10ºC |
0.025 |
| Input
Impedance |
Ω |
410
± 30 |
| Output
Impedance |
Ω |
350
± 3 |
| Insulation |
MΩ |
>
2000 / 50 VDC |
| Recommended
Excitation |
V |
10 |
| Maximum
Excitation |
V |
15 |
| Compensated
Temperature Range |
ºC |
-
10 ~ 40 |
| Operation
Temperature Range |
ºC |
-
20 ~ 60 |
| Safe
Overload |
%
F.S. |
150 |
| Ultimate
Overload |
%
F.S. |
300 |
| Cable
Size |
mm |
Ø 5
× 2000 |
| Platform
Size |
mm |
600
× 700 |
|
Red : + Excitation
Black : + Excitation Green : + Signal
White : + Signal |
|

|
| Cap |
A |
B |
C |
D |
| inch |
mm |
| 50
~ 1000 kg |
60 |
7.85 |
24.9 |
5
/ 16 ~ 18 20 |
M8
20 |
| 500
~ 2000 kg |
50 |
12.5 |
25 |
1
/ 2 ~ 20 20 |
M12
20 |
|