EX101 |
 |
|
Single-ended,
aluminum Load Cell.
Mainly used for electronic scale, balance,
capacity measure and industrial weighing system. |
|
| Specifications |
Unit |
Technical
Index |
| Capacity
: 3,
5, 6, 8, 10, 15, 20, 30, 50, 60, 100, 150, 200, 250 kg |
| Rated
Output |
mV
/ V |
2.0
± 10% |
| Zero
Balance |
%
F.S. |
±
2 |
| Non
- Linearity |
%
F.S. |
0.02 |
| Hysteresis |
%
F.S. |
0.02 |
| Repeatability |
%
F.S. |
0.02 |
| Creep
( 30min ) |
%
F.S. |
0.03 |
| Temperature
Effect on Output |
%
F.S. / 10ºC |
0.025 |
| Temperature
Effect on Zero |
%
F.S. / 10ºC |
0.025 |
| Input
Impedance |
Ω |
410
± 30 |
| Output
Impedance |
Ω |
350
± 3 |
| Insulation |
MΩ |
>
2000 / 50 VDC |
| Recommended
Excitation |
V |
10 |
| Maximum
Excitation |
V |
15 |
| Compensated
Temperature Range |
ºC |
-
10 ~ 40 |
| Operation
Temperature Range |
ºC |
-
20 ~ 60 |
| Safe
Overload |
%
F.S. |
150 |
| Ultimate
Overload |
%
F.S. |
300 |
| Cable
Size |
mm |
Ø 4
× 450 |
| Platform
Size |
mm |
250
× 300 |
|
Red : + Excitation
Black : + Excitation Green : + Signal
White : + Signal |
|

|
| Cap |
A |
B |
C |
D |
L |
M |
| 3
~ 50 kg |
130 |
30 |
106 |
22 |
15 |
M6 |
| 60
~ 250 kg |
130 |
50 |
106 |
22 |
15 |
M8 |
|
|